The 90W centrifugal fan plays a very important role in industrial production. During the use of 90W centrifugal fans, it is inevitable to encounter some special production conditions, which put forward very high requirements for the performance of 90W centrifugal fans. For example, lightning can cause significant damage to the 90W centrifugal fan system. Let's introduce how the 90W centrifugal fan system can cope with lightning better.
Aiming at the increasingly serious problem of lightning disasters on the blades of 90W centrifugal fan system, the main problems faced by the blades of 90W centrifugal fan in lightning protection design are analyzed, and the conclusions are as follows:
1) The risk assessment of lightning protection system design is only based on downward lightning, while most lightning strikes on 90W centrifugal fans are upward lightning instead. Therefore, in the lightning protection design of 90W centrifugal fan, the lightning strike frequency of upward lightning should be considered, so as to more reasonably and accurately evaluate the probability of lightning strike accidents of 90W centrifugal fan.
2) Rotating blades have a relatively special lightning inducing effect, so attention should be paid to the lightning protection design of 90W centrifugal fans.
3) The 90W centrifugal fan has a wide range of internal devices and complex structures. The lightning current intruded into the 90W centrifugal fan will be affected by current reflection, causing interference in its transient process. Considering that the motion characteristics of the blades of the 90W centrifugal fan have a significant impact on the current refraction and reflection coefficients, it is necessary to consider the complexity of the return stroke in the lightning protection design of the 90W centrifugal fan.
4) When a blade is struck by lightning, the CFRP laminate inside the blade generates significant energy dissipation, resulting in damage such as burning and deformation of the blade under the coupling effect of multiple physical fields such as electromagnetic, thermal, and force fields. In order to minimize the energy dissipation of CFPR laminate, suggestions are made for the number of down conductors and the installation method of CFRP laminate.
5) Induced lightning can generate transient electromagnetic fields near and inside the 90W centrifugal fan system, resulting in electromagnetic compatibility issues for key electromagnetic components of the 90W centrifugal fan. In the lightning protection design, necessary shielding measures should be taken to minimize the interference of nearby strong electromagnetic fields on the operation of internal components of the 90W centrifugal fan.
At present, significant research results have been achieved in lightning protection technology for 90W centrifugal fans. Literature [5] proposes a mathematical model for analyzing the lightning transient response of wind turbine towers considering the frequency variation of parameters, and expounds the impact of lightning stroke points and lightning current waveforms on the lightning transient response. Document [6] points out that carbon fiber composite materials have been widely used in 90W centrifugal fan blades to improve blade strength. The presence of this composite material will seriously affect the efficiency of lightning protection systems (LPS), so its impact must be considered thoroughly at the design stage. Literature [7] has studied the relationship between the lightning inducing ability of wind turbine blades and the grounding resistance of wind turbine generators, providing a reference for the simulation test design of grounding and lightning protection schemes for offshore wind turbines.
In summary, the introduction in this article is relatively detailed. When using a 90W centrifugal fan, we must pay attention to following these tips to avoid lightning, so that we can ensure the safety of the 90W centrifugal fan system. The 90W centrifugal fan can bring a lot of convenience to our industrial production, so it won't hurt at all.