High pressure fans play a very important role in industrial production, as they are often in operation due to their superior performance. However, if the high-pressure fan malfunctions, it will seriously affect production efficiency.
Burnout of the high-pressure blower motor is a common fault in the use of high-pressure blowers. The main reasons for motor burnout are motor phase loss, motor overload operation, mechanical faults, etc.
Burnout of the high-pressure blower motor is a common fault in the use of high-pressure blowers. The main reasons for motor burnout are motor phase loss, motor overload operation, mechanical faults, etc.
According to statistics, faults in the operation of three-phase asynchronous motors used for production account for about 85% of electrical faults caused by winding burnout, and about 15% of mechanical and other faults. Specifically, the reasons for winding burnout are mostly due to phase loss or overload operation, winding grounding, and short circuits between windings or turns.
Secondly, due to mechanical reasons such as rotor friction (motor scanning hole), insufficient oil deviation in the broken bearing, etc.), a series of wire packages in the motor have broken, with a black color indicating that the motor is burnt out first. However, electrical reasons leading to the burning of the high-voltage blower motor are the most common and quite complex. Some users, in order to shirk their responsibilities, have adopted the guarantee policy of Dongshan Technology's high-pressure fans. In most cases, unreasonable demands are made. In order to help sales personnel identify the true cause of the burning out of the high-voltage fan motor, I hereby focus on analyzing the causes of the motor winding burning out from an electrical perspective and proposing corresponding treatment methods.
1、 Phase loss operation
1. Fault phenomenon
Even if the motor cannot be started and can be started without load, the speed will gradually increase and make a buzzing sound; The motor smokes and has a fever, with a burning smell.
2. Inspection results
After removing the motor end cover, it can be seen that there are 1/3 or 2/3 pole phase coils at the end of the coil, which are either burnt or dark brown.
3. Fault causes and handling methods
(1) Due to poor contact and mechanical damage in the fuse circuit of the motor power supply circuit, the fuse of a certain phase has blown.
(2) The three-phase fuse specifications of the motor power supply circuit are different, and fuses with small capacity will burn out. Please replace with a fuse of the same specification based on the power of the motor.
(3) Poor contact (burns or looseness) between the contacts of the switch (isolation switch, rubber cover switch, etc.) and the contactor in the motor power circuit. Repair and adjust the dynamic and static contacts to ensure good contact.
(4) Missing a certain phase. Detect the broken wire position and firmly connect it.
(5) Temporary welding between motor windings resulted in poor contact. Carefully inspect the connecting wires of the motor winding and firmly weld them.
2、 Overload operation
1. Fault phenomenon
Due to the long-term operation of the high-voltage fan in the high-voltage area, the shaft power of the motor increases and the motor current exceeds the rated value; The temperature rise of the motor exceeds the rated temperature. Or, whether the motor is in overload operation when foreign objects are sucked in the high-pressure blower, or whether the lubricating grease or sand frame on the motor bearing is damaged; Friction between the stator and rotor iron cores, commonly known as sweeping.
2. Inspection results
All three sets of windings of the motor were burnt out.
3. Fault causes and handling methods
(1) When the high-pressure blower operates in the high-pressure area for a long time, it is necessary to release the pressure appropriately or replace the motor with a suitable power.
(2) Foreign objects being sucked into the high-pressure blower can cause overload on the motor and cause the motor coil to burn out. Check the front end of the high-pressure blower, handle foreign objects, and make it rotate flexibly.
(3) When the power supply voltage is too high or too low, it is necessary to install a three-phase power supply stabilization compensation plate. The motor is exposed to long-term humidity and corrosive gases, resulting in a decrease in insulation resistance.
(4) Insufficient oil in the bearings, mechanical eccentricity of the dry mill or rotor can cause the motor rotor to sweep the cylinder hole and the motor current to exceed the rated value. Firstly, carefully check the wear of the bearings and replace them with new ones if they are not qualified; Then, clean the bearings and inject an appropriate amount of lubricating grease. Then, check the motor end cover. If the center hole of the end cover is worn and the rotor is different, please handle or replace the end cover.